Search
Filters

LMCVR-500V

MULTIFUNCTION, COMBINED VOLTAGE RELAY, 24-230VAC/DC, 0.1-30S
SKU: LMCVR-500V
*
S$244.80
  • Under or Over voltage monitoring (selectable)
  • 5 Selectable voltage ranges (20V, 50V, 100V, 200V or 500V)
  • Adjustable Trip level, Hysteresis and Time delay + Latch
  • Isolated Auxiliary supply
  • SPDT Relay output
  • 17.5mm wide, DIN Rail mount
  • UL Listed

The product is designed to monitor voltage across a load (for example). An auxiliary supply (required to power the unit) must be present for the product to function.

Two monitoring modes available:

Under voltage:
In normal operation, the relay is in the energised state (monitored voltage above the set trip level). When the voltage decreases below the trip level, the relay will de-energise after the set delay. The voltage must increase above the trip level plus the hysteresis before the relay will re-energise.

Over voltage:
In normal operation, the relay is in the energised state (monitored voltage below the set trip level). When the voltage increases above the trip level, the relay will de-energise after the set delay. The voltage must decrease below the trip level minus the hysteresis before the relay will re-energise.

  • Under or Over voltage monitoring (selectable)
  • 5 Selectable voltage ranges (20V, 50V, 100V, 200V or 500V)
  • Adjustable Trip level, Hysteresis and Time delay + Latch
  • Isolated Auxiliary supply
  • SPDT Relay output
  • 17.5mm wide, DIN Rail mount
  • UL Listed

The product is designed to monitor voltage across a load (for example). An auxiliary supply (required to power the unit) must be present for the product to function.

Two monitoring modes available:

Under voltage:
In normal operation, the relay is in the energised state (monitored voltage above the set trip level). When the voltage decreases below the trip level, the relay will de-energise after the set delay. The voltage must increase above the trip level plus the hysteresis before the relay will re-energise.

Over voltage:
In normal operation, the relay is in the energised state (monitored voltage below the set trip level). When the voltage increases above the trip level, the relay will de-energise after the set delay. The voltage must decrease below the trip level minus the hysteresis before the relay will re-energise.

  • Monitoring function: Under or Over voltage
  • Monitored voltage ranges: 2 – 20V, 5 – 50V, 10 – 100V, 20 – 200V or 50 – 500V AC/DC
  • Trip level: 10 – 100% of selected range
  • Hysteresis: 2 or 10%
  • Time delay: 0.1 – 30s
  • Aux. supply voltage*: 12 – 60V AC/DC or 24 – 230V AC/DC
  • Output: SPDT 8A @ 250V (AC1)
  • Dimensions(mm): W:17.5 x H:89 x D:66.5

* To be specified when ordering

Write your own review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*