P9630

OVERCURRENT DETECTION (IDT) P9630
SKU: P9630
*
S$573.40
  • Overcurrent detection (IDT)
  • Adjustable Low-set and High-set tripping thresholds (with option to disable High-set)
  • Adjustable Time multiplier setting (Low-set only)
  • Instantaneous tripping on High-set
  • LED indication shows when tripped
  • Test and Reset buttons
  • 96 x 96mm, Panel Mount

An Overcurrent relay that will monitor and detect when the measured current on any phase exceeds the set trip threshold and de-energise the output relay after a pre-determined delay based the level of current measured and Time multiplier setting. Two levels of tripping thresholds are provided (both adjustable) allowing the user to set a “Low-set” and “High-set” trip point. The operation of the tripping curve is only applicable when the Low-set trip point is exceeded. If the measured current exceeds the High-set trip point, the relay de-energises straight away.

An auxiliary supply (required to power the unit) must be present for the product to function.

  • Overcurrent detection (IDT)
  • Adjustable Low-set and High-set tripping thresholds (with option to disable High-set)
  • Adjustable Time multiplier setting (Low-set only)
  • Instantaneous tripping on High-set
  • LED indication shows when tripped
  • Test and Reset buttons
  • 96 x 96mm, Panel Mount

An Overcurrent relay that will monitor and detect when the measured current on any phase exceeds the set trip threshold and de-energise the output relay after a pre-determined delay based the level of current measured and Time multiplier setting. Two levels of tripping thresholds are provided (both adjustable) allowing the user to set a “Low-set” and “High-set” trip point. The operation of the tripping curve is only applicable when the Low-set trip point is exceeded. If the measured current exceeds the High-set trip point, the relay de-energises straight away.

An auxiliary supply (required to power the unit) must be present for the product to function.

  • Monitoring function: Overcurrent
  • Tripping characteristic*: Inverse Definite Time
  • Low-set trip threshold: 2 – 6A
  • High-set trip threshold: x1 – x10 or disable
  • Time multiplier: 0.05 – 1 (Low-set only)
  • Aux. supply voltage*: 115VAC or 230VAC
  • Output: SPDT 8A @ 250V (AC1)
  • Dimensions(mm): W:96 x H:96 x D:100
  • Product standard(s): IEC 60255-151

* To be specified when ordering